Subsequent qualification — 2026-10-18

DC-M4 — Calibration and Native Mechanics Qualification now qualifies designed K/lambda/theta numerical recovery and an opt-in full-state source using actual native mesh mechanics. Thirteen native and eleven Python tests plus5000 native steps and separate independent reconstruction pass. This advances the earlier native-integration boundary only for the sealed six-vertex mechanics fixture. Empirical four-parameter calibration, constant epsilon_A and whole-organism integration remain unresolved; the exact coarse closure witness is documented there. The original reference results below remain unchanged.

Status

COMPLETE — INDEPENDENTLY VERIFIED COMPUTATIONAL REFERENCE BUILD AND MEASUREMENT ONLY

Full target calibration and production integration remain unqualified.

Authority and independent evidence

The owner requests online independent chemical-source and kinetic evidence, then build/measure, and explicitly selects computational reference first. Entry 524fb8c85b35923fd4fd8e0d1b91abbff629f460; directive DC-M4-CHEMICAL-KINETIC-REFERENCE-001. Follows DC-M4 — Justified Reference and Variable/Unit Mappings.

The independently published Avanzini/Falasco/Esposito2020 model, equations5–7 and Figure1, supplies a closed six-species/four-reversible-channel chemical reference with explicit published rates, initial state and units. We reproduce its full elementary equations, not its coarse-grained approximation. Published numerical values are computational specifications, not empirical ATP constants. Original documents are hash-receipted in external custody; no external executable or full-text Git redistribution.

Rao/Esposito2016 provides independent chemical-affinity/rate-ratio and free-energy accounting evidence. Its heat/enthalpy distinction is preserved.

Source and kinetic mappings established at reference level

The full finite chemical state owns ideal-mixture free energy and each reaction affinity. Remaining substrate equivalents A_src and product equivalents W_src conserve their sum. They are material bookkeeping, not constant-energy packets; their coarse pair does not close full source kinetics. Operational bound-enzyme a=ES+ESS, b=E and P=E+ES+ESS conserve a+b=P; their net kinetics is j2−j4, not native cubic autocatalysis.

Thermal energy/amount maps are explicit, including normalized theta=1. SI/packet scales and a native biological identity remain independently required. No production K, lambda, theta or epsilon_A is identified.

What was built

An executable full chemical reference and a separately declared new reciprocal mechanical extension: fixed prepared occupancy anchor, two-port shifted spring, native scalar stretch receiver, reaction-specific affinity bias and gradient-flow mechanics. It begins with zero elastic preload and finite owned chemical preparation. Chemical volume remains fixed while mechanical length changes, so this is not a native edge-dilution adapter. Design coefficients are explicit illustrative inputs.

Its complete differential free-energy balance equals negative chemical and drag dissipation. Free-energy loss is not called chemical heat. No clipping, material projection, source top-up or residual repair.

Measured computational result

A protocol sealed before execution fixes six cases and two step sizes: published unloaded chemistry, coupled reference, zero coupling, no chemistry, time rescaling and equilibrium. All budgets pass unchanged;11 focused tests pass.

At normalized time60, coupled length1→0.976380491163, minimum0.975365371480. Receiver peak energy0.000303432461171; final0.000278940598857. Zero-coupling/no-chemistry/equilibrium controls remain unloaded. Time-rescaled endpoint matches exactly in this execution.

Independent midpoint endpoint discrepancies are below9e−12. Maximum coupled fine-step material drift3.34e−15; largest unrepaired free-energy/dissipation defect1.76e−8. These are observed numerical checks, not rigorous interval bounds or biological uncertainty. Finite-time relaxation is not declared complete. Raw simulated trajectories remain separate from independent published source evidence and target calibration observations.

The first measurement harness attempt failed on a budget-field name before publishing results; the lookup was corrected without changing the sealed design or numerical budgets.